Installation andOperating Instructions Pool Safety SystemENFor the versions: y BASIC y STANDARD y PROFESSIONAL

Seite 2

102.3 Operating principle "passive mode"Pool monitoring outside normal bathing hoursFor monitoring the pool outside normal bathing hours th

Seite 3

112.5 Package contentsSENSOR SENSOR SENSORAlarm box with siren1 Warning lights 2 12 V Connection3 Pool sensor connection 4 Spare connection

Seite 4

12USB cableMagnetic adapter (connects monitoring brace-let / USB cable)USB plug-in mains adapterMonitoring bracelet (1 pcs.)1 Red and green LEDs2 W

Seite 5 - 1.2 Safety notes

133 Using the System for the First Time y Read the installation and operating instructions. y Charge the monitoring bracelet battery, see Charging t

Seite 6 - 2 Overview

144 Installing the BlueFox System y Dispose of packaging materials in an environmentally acceptable manner. y Read the Installation and operating ins

Seite 7 - PROFESSIONAL version

154.1.2 Installing the alarm box y Hold the bracket to the wall and mark the drilling positions.122x34Tab facing up Danger! Electric shock risk! Con

Seite 8

16Procedure y Connect the 12 V cable to the alarm box and screw tight. y Fix the 12 V cable. Danger! Electric shock risk!Do not use extension cables

Seite 9

17 SENSOR SENSOR SENSOR3 y Ensure that the plug on the pool sensor cable is dry. y Connect the pool sensor cable to the alarm box and screw tig

Seite 10 - 2.4 Intended use

18 Caution! Incorrect tting of the pool sensor will prevent proper monitoring of the swimming pool. The side of the pool sensor marked "Sensor&

Seite 11 - 2.5 Package contents

195 Alarm box operation7 8 9 C 4 5 6 0 1 2 3 OK Active mode (bathing hours)Monitoring using only monitoring braceletsDeletes the last figure enter

Seite 12 - PRO Test unit

21 Explanation of Symbols and Safety Notes ... 51.1 Explanation of symbols ...

Seite 13 - PRO pool sensors), see

20Procedure:Press the button. If PIN protected: Enter the 4-gure PIN and then press OK (see page 27).Following successful activation the LED along

Seite 14 - Minimum 2,0 m

215.3 Activating the "Passive mode"Pool monitoring outside bathing hoursFor pool monitoring outside bathing hours the “Passive mode” must

Seite 15

226 System settings Warning!When the “System settings” operating mode is activated, the BlueFox system does not monitor the pool and cannot trigger

Seite 16 - Swimming pool

23System tests Procedure / notesPRO STD Sending a test alarm to the radio moduleEnter "0001" and press OK.The alarm box sends a test alarm t

Seite 17

24System settings Procedure / notesCancelling the siren Warning! Risk of drowning because the acoustic alarm is inoperable. Only deactivate the siren

Seite 18

25System settings Procedure / notesChanging the PIN Enter "2001" and press OK. Warning! Risk of drowning due to unintended deactiva-tion of

Seite 19 - 5 Alarm box operation

26System settings Procedure / notesResetting the alarm box to the factory defaultsAll of the BlueFox system settings will be reset to their factory de

Seite 20

276.2 Entering the PINA PIN (Personal Identication Number) can be set to prevent operating modes from unintentional change. See Changing the PIN, pa

Seite 21

287 Using the SystemThis section describes the optimum use of the system in day-to-day operations.Activate the “Active mode”or “Passive mode”. See 7.

Seite 22 - 6 System settings

297.4 After use y Dry the monitoring bracelet using a cloth. y Charge the battery if the red LED on the monitoring bracelet ashes at one-sec-ond int

Seite 23 - PRO STD

37 Using the System ... 287.1 Using active mode ...

Seite 24

308 Testing active mode Caution! Risk of hearing damage caused by the sound pressure level from the siren! Wear hearing protection; keep children aw

Seite 25

319 Monitoring braceletMonitoring bracelet 1 Red LED2 Green LED3 Water contacts (gold-plated)Rear5 Connection for magnetic adapter (charging and

Seite 26

32 y Charge the battery if the red LED on the monitoring bracelet ashes at one-second intervals (when the unit is out of the water). Note: If the re

Seite 27 - 6.2 Entering the PIN

339.3 Programming the alarm depth and timeThe alarm depth and alarm time are programmed using the BlueFox control soft-ware. Installation of the soft

Seite 28 - 7 Using the System

3412543Select the alarm depth and associated alarm time 1:Select a pre-set value 2 or use the slider 3 to enter the pre-dened alarm depth and alarm t

Seite 29 - 7.5 Using passive mode

359.4 Calling the status / Clearing the alarm / Resetting678 y Click Call Status to retrieve the battery and alarm status 6. y Clear Alarm 7. y Click

Seite 30 - 8 Testing active mode

3610 BlueFox Control Software10.1 Hardware requirementsFor the installation and problem-free use of the BlueFox control software a Win-dows compatib

Seite 31 - 9 Monitoring bracelet

37 y Click BlueFox. y Click Save, select the destination folder, then Save.The download will start. y Open folder. y Double-click on the Zip le. y Do

Seite 32

38Installation of the BlueFox controlsoftware is interrupted. The BlueFox control software requires the Micro-soft .NET Framework 3.5program. y Click

Seite 33

3910.4 Using the BlueFox control softwareSee Programming the alarm depth and time, P. 33 and Calling the status / Clearing the alarm / Resetting, P.

Seite 34

413 Troubleshooting ... 4114 Technical Specifications ...

Seite 35

4011 Meaning of the monitoring bracelet LED displays11.1 The monitoring bracelet in useRed LED Green LEDRed ashes 1x /sec.: Low battery. y Charge

Seite 36 - 10 BlueFox Control Software

4112 Maintenance / Service y Dry the monitoring bracelet with a cloth after use. y Charge the battery if the red LED on the monitoring bracelet ashe

Seite 37

42Problem Possible cause SolutionDuring operation the alarm box transmits a short tone sequence.Power failure Have the mains con-nection checked by an

Seite 38

4314 Technical Specifications14.1 GeneralMaximum number of monitoring bracelets: unlimitedAlarm boxAC 100-240 V, 50 Hz Power consumption in standby:

Seite 39 - 10.6 Updates

4414.3 Power failure If the power should fail the alarm box will sound a sequence of warning tones. See also Safety notes, P. 6.The operating mode of

Seite 40

4516 WarrantyDeep Blue AG provides a product warranty in accordance with the laws of your country, but for a period of at least two years commencing

Seite 41 - 13 Troubleshooting

4617 DisposalProtect the environment! Packaging and old equipment contain recoverable materi-als that should be recycled.The BlueFox system or compon

Seite 42

4719 Configuration tableName Colourmonitoring braceletAlarm depth Alarm time(seconds)

Seite 43 - 14 Technical Specifications

Deep Blue AGEngenbühl 130 CH-5705 Hallwil Switzerland Tel: +41 (0) 62 767 77 99www.bluefox-poolsafety.com [email protected] V1.024.01.2013

Seite 44 - 15 Disclaimer

51 Explanation of Symbols and Safety Notes1.1 Explanation of symbols Safety notesIn the text, safety notes are marked with a warning triangle.Signa

Seite 45 - 16 Warranty

6 Safety notes y Observe the safety notes contained in these installation and operat-ing instructions. y Risk of drowning! Initiate rescue immediatel

Seite 46 - 18 Optional Accessories

7BlueFox can be supplied in the following versions: BASIC, STANDARD and PROFES-SIONAL. Information that only applies to the STANDARD and/or PROFESSION

Seite 47 - 19 Configuration table

82.2 Operating principle "Active mode"Pool monitoring during bathing hoursFor pool monitoring during bathing hours the active mode must b

Seite 48 - 24.01.2013

9If no button is pressed, all alarms will be cancelled 10 seconds after the monitoring bracelet is taken out of the water. All alarms are cancelled 6